Transair® Aluminum Pipe Quick Assembly Brackets
Installation Instructions 2"(50mm) – 2-1/2"(63mm)

< Back to Previous Page

Installation Guidelines
1. Transair pipe and hoses: Transair pipe should be protected from mechanical impact, particularly if exposed to collision with fork-lift trucks or when sited in an environment with moving overhead loads. Similarly, rotation of the pipe and pipe supports should be avoided. Transair pipe must not be welded.

2. Expansion and contraction: Expansion and contraction of the system should be calculated prior to installation. The system designer and installer should calculate the elongation or retraction of each Transair line according to the recommendations in this installation guide.

3. Situation to avoid: Installation within a solid mass (concrete, foam, etc.), the hanging of any external equipment to Transair pipe, the use of Transair for grounding or as a support for electrical equipment, and exposure to chemicals that are incompatible.

4. When assembling Transair connectors, do not interchange the nuts with different Transair bodies due to our calibration process.


Quick Assembly Brackets

Tools
Click Here for the Tools Page
drilling tool Drilling tool for aluminum pipe
ref. 6698 02 01
drilling jig Drilling jig for aluminum pipe
ref. 6698 01 02
deburring tool Deburring tool for aluminum pipe
ref. 6698 04 02
marking tool Permanent marker pen
pipe cutter tool Drill

Procedure
1. Mark the pipe at the desired position for the bracket. The mark should be placed on one of the locator marks so that multiple brackets are correctly aligned, when several take-off points are required. Place the 2 1/2" drilling jig in a vice or on the floor and place the pipe in the jig. Ensure that the line marked on the pipe is centred within the drilling guide: two marks on either side of the jig’s upper side provide a rapid indication of the pipe’s positioning. Tighten the locking clamp to secure the pipe and drill using the 1" drilling tool. [Recommended rotation speed: 650 rpm] Note: Drill without lubrication.
2. Loosen the locking clamp and release the pipe, remove any chips and deburr the hole. Repeat the operation for the number of brackets that you wish to fit.
3. Position the quick assembly bracket using its location hole
4. Tighten the screw



Back to Main Training Page
 ✉ Email this Page 

Also Available from mdi

Powerex Oil-less
Air Compressors

Finite Filters
www.powerexsales.com
Coxreels
Hose Reels

Coxreels Hose Reels
www.coxreelsales.com
Drain-All
Condensate Drains

Coxreels Hose Reels
www.drainallsales.com
mdi
   
TransairPipeSales.com is owned and operated by mdi, Manufacturers Distributor, Inc. mdi is an Authorized Parker Transair Piping System Distributor. Click Here to view the mdi Line Sheet.