Contact mdi

Get Free Quote:
Contact Form
sales@
transairpipesales.com

 Hours:
7:30AM - 7:00PM ET
Monday - Friday


Transair Since 1996!

Call mdi Today!

Manufacturers Distributor, Inc.
11205 Challenger Ave
Odessa, FL 33556
United States

SCOUT Technology - Transair Pipe Systems

Wireless Condition Monitoring for Transair Compressed Air Systems

Photo showing a SCOUT sensor-embedded connector in a Transair Aluminum Pipe system.

  Models

Pressure, Temperature, and Humidity Sensors

Photo showing Transair SCOUT pressure, temperature, and humidity sensors.

Features:

  • For commonly used pressure range of 0 to 150 psi
  • User-definable measurement units in software
  • Ports: ¼" female NPTF
  • Corrosion-resistant materials for challenging environments

Drag your finger across the table to scroll

Assembly Nomenclature Examples
6676 25 00 PT Attribute
6676 25 00 Base Fitting PN
PT Type of Sensor

Drag your finger across the table to scroll

Sensor Technical Information
Pressure Range 0 to 150 psi
Burst Pressure 4x
Temperature Range -4°F to 167°F
Body Material Acetal
Body Seals Nitrile
Wetted Materials Acetal, Nitrile, Silicone
Certifications FCC
Battery CR2450 (Panasonic® suggested brand)
IP (Ingress Protection) Rating IP65
Port 1/4" Female NPTF
Scan and Transmit Rate 5 Seconds to Variable Rate

Photo of a Transair SCOUT monitor integrated into a Transair pipe-to-pipe connector.

Pressure

  • Operating Range: 0 to 150 psi
  • Accuracy (Best Fight Straight Line, -40°F to 176°F): 0.75%
  • Resolution (at 77°F): 0.03 psi
  • Total Error Band (0 to 50 psi): 2%

Sensor Only

Drag your finger across the table to scroll

Part #
SNPT-10-2-4FP-KY

Photo of a Transair SCOUT pressure sensor.

Drag your finger across the table to scroll

Pipe-to-pipe connector with sensor
Part # ØD
  inch mm
6676 25 00 PT 1.0 25
6676 40 00 PT 1.6 40
6676 50 00 PT 2.0 50
6676 63 00 PT 2.5 63

Humidity

  • Operating Range: 0 to 100% Relative Humidity (RH)
  • Accuracy (77°F, 20% RH to 80% RH, at Ambient Pressure): ±5% RH Max
  • Resolution (at 77°F): 0.1% RH
  • Response Time: 10 Seconds

Sensor Only

Drag your finger across the table to scroll

Part #
SNHT-10-2-4FP-KY

Photo of a Transair SCOUT humidity sensor.

Drag your finger across the table to scroll

Pipe-to-pipe connector with sensor
Part # ØD
  inch mm
6676 25 00 HT 1.0 25
6676 40 00 HT 1.6 40
6676 50 00 HT 2.0 50
6676 63 00 HT 2.5 63

Temperature

  • Fluid Temperature Range: 14°Fto 185°F
  • Accuracy (77°F): ±2.5%
  • Resolution (14° to 120°F): 1°F
  • Response Time: 10 Seconds

Sensor Only

Drag your finger across the table to scroll

Part #
SNT-10-2-4FP-KY

Photo of a Transair SCOUT temperature sensor.

Drag your finger across the table to scroll

Pipe-to-pipe connector with sensor
Part # ØD
  inch mm
6676 25 00 T 1.0 25
6676 40 00 T 1.6 40
6676 50 00 T 2.0 50
6676 63 00 T 2.5 63

Power Sensors

Photo of a Transair SCOUT power sensor.

Features:

  • User-definable measurement units in software
  • Ports: ½" male NPT thread with bulkhead nut for use with 7/8" knock out size
  • Corrosion-resistant materials for challenging environments
  • Split-core current transformer with 1-¼" opening for passing through existing electrical conductors
  • 8-foot long twisted-pair current transformer lead wires with locking connector

Drag your finger across the table to scroll

Transmitter Technical Information
Temperature Range -4°F to 167°F
Body Material Acetal / Brass (Nut)
Certifications FCC
Battery CR2450 (Panasonic® suggested brand)
IP (Ingress Protection) Rating IP65
Port ½" Male NPT w/Bulkhead Nut
Scan and Transmit Rate 5 Seconds to Variable Rate
Software Inputs Voltage and Number of Phases
Maximum Voltage 600V (on Bare Conductor)
Operating Frequency Range 50 Hz to 400 Hz
Current Linearity Accuracy ±1% (10% to 130% of Rated Current)
Phase Angle Offset <2° (Measured at Rated Current)
Current Transformer Certifications UL Recognized, CE and RoHS Compliant

Drag your finger across the table to scroll

Transmitter with Current Transformer
Part # Rated Current
SNC-050-2-8MP-KY 50 Amp
SNC-100-2-8MP-KY 100 Amp
SNC-150-2-8MP-KY 150 Amp
SNC-200-2-8MP-KY 200 Amp
SNC-250-2-8MP-KY 250 Amp
SNC-300-2-8MP-KY 300 Amp
SNC-400-2-8MP-KY 400 Amp
SNC-600-2-8MP-KY 600 Amp
SNC-800-2-8MP-KY 800 Amp

Flow Sensors

Flow Monitoring

  • Accuracy: 6% of Measuring Range
  • Response Time: 15 Seconds
  • Maximum Relative Humidity: 95%

Temperature Monitoring

  • Accuracy: ±1.8°F

Pressure Monitoring

  • Accuracy: ±1.5 psi

Drag your finger across the table to scroll

Technical Information
Pressure Range 0 to 150 psi
Burst Pressure 4x
Temperature Range -4°F to 167°F
Body Material Polycarbonate, Brass
Body Seals Nitrile
Wetted Materials Brass, Nitrile, Silicone
Full Range Cycles >1 Million
Certifications FCC
Battery CR123A (Duracell® suggested brand)
IP (Ingress Protection) Rating IP65
Port Transair Reducing Bracket
Scan and Transmit Rate 15 Seconds to Variable Rate


Photo of a Transair SCOUT flow sensor for 1 inch (25 milimeter), 1-1/2 inch (40 milimeter), or 2 inch (50 milimeter) pipe sizes.

Flow Sensor Reducing Bracket


Drag your finger across the table to scroll

Simple reducing bracket with sensor
Part # ØD Maximum Calibrated Measurement Range
  inch mm SCFM Nm3/h Nl/min
RA69 25 FL 1.0 25 60 102 1 699
RA69 40 FL 1.6 40 200 340 5 663
RA98 50 FL 2.0 50 300 510 8 495


Photo of a Transair SCOUT flow sensor for 2-1/2 inch (63 milimeter) pipe sizes.

Flow Sensor Reducing Bracket


Drag your finger across the table to scroll

Simple reducing bracket with sensor
Part # ØD Maximum Calibrated Measurement Range
  inch mm SCFM Nm3/h Nl/min
EA98 63 FL 2.5 63 400 680 11 327


Photo of a Transair SCOUT flow sensor for 3 inch (76 milimeter) or 4 inch (100 milimeter) pipe sizes.

Flow Sensor Reducing Bracket


Drag your finger across the table to scroll

Simple reducing bracket with sensor
Part # ØD Maximum Calibrated Measurement Range
  inch mm SCFM Nm3/h Nl/min
RR63 98 L1 FL 3.0 76 600 1 020 16 990
RR63 98 L3 FL 4.0 100 1 100 1 701 28 317

Communication

Features

  • Wireless star topology with sensor nodes communicating directly to the primary receiver node (PRN)
  • PRN connected to collection server via USB 2.0 port
  • Wireless signal strength and battery voltage reported in software
  • Data buffer storage for communication interruptions
  • Data transmission to the cloud through wireless, ethernet or cellular options

Drag your finger across the table to scroll

Technical Information
Wireless Frequency 902 to 928 MHz
Temperature Range -4°F to 167°F
Data Upload Rate 60 Seconds (default) to Variable Rate
AC Power Input 100 to 240V ~ 1.8A, (50 to 60Hz)
Standard External Communication Modes Ethernet, Wireless

Photo of a Transair SCOUT collection server.

SCOUT Collection Server

Collection Server

Drag your finger across the table to scroll

Part # Cellular Modem Options
  Ethernet Wifi CDMA GPRS
SN-CS-1    
SN-CS-2  
SN-CS-3  

Primary Receiver Node

Drag your finger across the table to scroll

Part #
SPRN-2

Photo of a Transair SCOUT optional enclosure for collection servers.

Optional Enclosure

Optional Enclosure

Impact and corrosion-resistant polycarbonate enclosure with a NEMA 4X rating for indoor and outdoor use, non-hazardous dust, washdown, and splash applications. Dimensions: 11"w x 15"d x 5"h

Drag your finger across the table to scroll

Part #
SN-CS-EN

Photo of a Transair SCOUT collection server mounting kit.

Collection Server Mounting Kit

Collection Server Mounting Kit

Corrosion-proof aluminum shelf with 1-½" backsplash, pre-drilled gusset supports and two fasteners for long-lasting durability and dependability. Dimensions: 24"w x 12"d

Drag your finger across the table to scroll

Part #
SN-CS-MK

  Features


Having accurate, timely readings on the performance of your compressed air piping system can mean the difference between identifying a problem before it occurs, or incurring added costs for equipment repairs…not to mention lost revenue.

Transair powered by SCOUT Technology helps you keep your system healthy and operating efficiently. SCOUT consists of a wide range of sensors that provide consistent and accurate readings for pressure, temperature, humidity, power, and flow. The system collects data so you can take the necessary steps to optimize your compressed air equipment and your system’s performance. The easy-to-use web-based interface also alerts the user to unexpected conditions that may damage components and equipment over time.

SCOUT Technology puts vital information and analytics in the palm of your hand to ensure your compressed air system is running at optimum levels. Let SCOUT Technology MONITOR your Transair compressed air piping system, ALERT you to system changes, and provide DATA that helps reduce downtime and increase productivity.

  Dimensions

Pressure, Temperature, and Humidity Sensors


Diagram showing the dimensions of a SCOUT pressure, temperature, or humidity sensor.

Dimensions for Pressure, Temperature, or Humidity Sensors



Diagram showing the dimensions of a Transair SCOUT pipe-to-pipe connector with integrated pressure, humidity, or temperature sensor.

Dimensions for Connector with Pressure Sensor


Drag your finger across the table to scroll

Pipe-to-pipe connector with sensor
Part # ØD Length Offset Height
  inch mm inch mm inch mm inch mm
6676 25 00 PT 1.0 25 5.96 151.5 3.78 96.0 3.0 76.2
6676 40 00 PT 1.6 40 8.07 205.5 4.49 114.0 3.4 86.4
6676 50 00 PT 2.0 50 6.93 171.0 1.97 50.0 3.6 92.5
6676 63 00 PT 2.5 63 6.75 171.5 1.97 50.0 3.9 99.1


Diagram showing the dimensions of a Transair SCOUT pipe-to-pipe connector with integrated pressure, humidity, or temperature sensor.

Dimensions for Connector with Humidity Sensor


Drag your finger across the table to scroll

Pipe-to-pipe connector with sensor
Part # ØD Length Offset Height
  inch mm inch mm inch mm inch mm
6676 25 00 HT 1.0 25 5.96 151.5 3.78 96.0 3.0 76.2
6676 40 00 HT 1.6 40 8.07 205.5 4.49 114.0 3.4 86.4
6676 50 00 HT 2.0 50 6.93 171.0 1.97 50.0 3.6 92.5
6676 63 00 HT 2.5 63 6.75 171.5 1.97 50.0 3.9 99.1


Diagram showing the dimensions of a Transair SCOUT pipe-to-pipe connector with integrated pressure, humidity, or temperature sensor.

Dimensions for Connector with Temperature Sensor


Drag your finger across the table to scroll

Pipe-to-pipe connector with sensor
Part # ØD Length Offset Height
  inch mm inch mm inch mm inch mm
6676 25 00 T 1.0 25 5.96 151.5 3.78 96.0 3.0 76.2
6676 40 00 T 1.6 40 8.07 205.5 4.49 114.0 3.4 86.4
6676 50 00 T 2.0 50 6.93 171.0 1.97 50.0 3.6 92.5
6676 63 00 T 2.5 63 6.75 171.5 1.97 50.0 3.9 99.1

Power Sensors


Diagram showing the dimensions of a Transair SCOUT power sensor.

Dimensions for SCOUT Power Sensors


Flow Sensors


Diagram showing the dimensions of a Transair SCOUT flow sensor for 1 inch (25 milimeter), 1-1/2 inch (40 milimeter), or 2 inch (50 milimeter) pipe sizes.

Dimensions for 1", 1-1/2", or 2" Flow Sensors


Drag your finger across the table to scroll

Simple reducing bracket with sensor
Part # ØD Height
  inch mm inch mm
RA69 25 FL 1.0 25 4.9 124.0
RA69 40 FL 1.6 40 5.4 137.4
RA98 50 FL 2.0 50 6.0 152.4


Diagram showing the dimensions of a Transair SCOUT flow sensor for 2-1/2 inch (63 milimeter) pipe sizes.

Dimensions for 2-1/2" Flow Sensors


Drag your finger across the table to scroll

Simple reducing bracket with sensor
Part # ØD Height
  inch mm inch mm
EA98 63 FL 2.5 63 6.5 165.9


Diagram showing the dimensions of a Transair SCOUT flow sensor for 3 inch (76 milimeter) or 4 inch (100 milimeter) pipe sizes.

Dimensions for 3" or 4" Flow Sensors


Drag your finger across the table to scroll

Simple reducing bracket with sensor
Part # ØD Height
  inch mm inch mm
RR63 98 L1 FL 3.0 76 7.3 184.4
RR63 98 L3 FL 4.0 100 8.7 219.7

  Catalogs

  Contact mdi

Please fill out the form below and your personal mdi product expert will email you your quote. The more information that you provide the quicker we can send you a quote. Sending an incomplete quote request could mean that we have to contact you for necessary information before sending your quote. And know that our knowledgeable sales staff is standing by to help you with your order and with any questions.

Required fields are marked with (*).







Please include your contact information so that we may reply to your request. Your contact information is private and will not be sold to any third party or used negatively in any way.















 Please fill out the required fields above in order to submit your quote request.





mdi does not advertise prices online. The cost of products is subject to change over time. In order to extend to you the best price that we can offer, we prefer to create written and emailed quotes which reflect any discounts or promotions currently available. Some products can be quoted over the phone, and expediting quotes and orders is always available per request.

See our Terms and Conditions for more information about the mdi sales process.


Call us any time Monday through Friday 7:30 AM to 5:30 PM EST.

Phone: (813) 241-4900 | Toll Free: 800-761-4298
Fax: (813) 571-0422 | Email or Fill Out the Form Above